<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01832nam a2200265Ia 4500</leader>
  <controlfield tag="003">MX-MdCICY</controlfield>
  <controlfield tag="005">20260521091711.0</controlfield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="c">CICY</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">B-19755</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Dielectric breakdown behavior of ferroelectric ceramics: the role of pores</subfield>
  </datafield>
  <datafield tag="490" ind1="0" ind2=" ">
    <subfield code="v">Journal of the European Ceramic Society, 41(4), p.2533-2538, 2021</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">Dielectric breakdown is a fundamental issue for ferroelectric ceramics. In this work, a phase-field method is introduced to study the breakdown behavior of ferroelectric ceramics with pores randomly distributed. Effects of the position and the size of pores on the breakdown behavior are analyzed. Results indicate that the position of pores, for example in grains or at grain boundaries, has a significant influence on the breakdown strength of ferroelectric ceramics. The nominal breakdown strength of ferroelectric ceramics with 2 percent pores at grain boundaries is almost 50 percent higher than 2 percent pores in grains. Further, for ferroelectric ceramics with a certain porosity, the smaller the pore size, the higher the breakdown strength. As the nominal pore size decreases from 2.5 to 1, the nominal breakdown strength is enhanced from 0.73 to 1.16. Such results agree well with the widely accepted Gerson-Marshall model and previously published experimental observations.</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="4">
    <subfield code="a">DIELECTRIC BREAKDOWN</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="4">
    <subfield code="a">FERROELECTRIC CERAMICS</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="4">
    <subfield code="a">PORES</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="4">
    <subfield code="a">SIZE EFFECT</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="4">
    <subfield code="a">PHASE-FIELD METHOD</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2="2">
    <subfield code="a">Cai, Z.</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2="2">
    <subfield code="a">Feng, P.</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2="2">
    <subfield code="a">Zhu, C.</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2="2">
    <subfield code="a">Wang, X.</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
    <subfield code="u">https://drive.google.com/file/d/1lCtiDvWaKA_gRsaCn3cTIK7iyzAKTzPR/view?usp=drivesdk</subfield>
    <subfield code="z">Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="2">Loc</subfield>
    <subfield code="c">REF1</subfield>
  </datafield>
  <controlfield tag="008">250602s9999    xx |||||s2   |||| ||und|d</controlfield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">29813</subfield>
    <subfield code="d">29813</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">Loc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="8">F1</subfield>
    <subfield code="a">CICY</subfield>
    <subfield code="b">CICY</subfield>
    <subfield code="c">RE</subfield>
    <subfield code="d">2025-06-25</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">B-19755</subfield>
    <subfield code="r">2025-06-25 16:24:36</subfield>
    <subfield code="w">2025-06-25</subfield>
    <subfield code="y">REF1</subfield>
  </datafield>
</record>
