<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Evaluation of Transient Electromagnetic Soundings for Deep Detection of Conductive Fluids</title>
  </titleInfo>
  <name type="personal">
    <namePart>Stewart, M.</namePart>
  </name>
  <name type="personal">
    <namePart>Gay, M.C.</namePart>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">xx</placeTerm>
    </place>
    <dateIssued encoding="marc">9999</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">und</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">electronic</form>
  </physicalDescription>
  <abstract>Transient electromagnetic sounding methods (TEM)have several advantages over DC resistivity soundings. The principal advantage is that sounding depths several times the receiver-transmitter spacing can be achieved, resulting in less cumbersome field work and more flexible sounding site selection. The TEM method was tested using a commercially available instrument (Geonics EM-37)in the Gulf Springs region of west-central Florida to locate the saltwater interface in the Floridan Aquifer. The Floridan is a thick (200 m), unconfined, karstic, carbonate aquifer within the study area. High annual rainfall and internal drainage create a deep and dynamic interface. Eighty transient soundings were completed in 18 field days. Seventy-one soundings used a square 80 m × 80 m transmitter loop, and the other nine used a 160 m × 160 m coil. The interface was easily detected from a minimum depth of 60 m to its maximum depth of about 140 meters. Also, a high-resistivity, low-porosity zone was detected at depths ranging from 180-250 meters. The TEM data compare well with available chloride concentration data. The TEM interface corresponds to chloride values in excess of 200-400 mg/1. The sounding curves obtained suggest that with presently available instruments the TEM method is not well-suited for shallow soundings (less than 40-50 meters). Copyright © 1986, Wiley Blackwell. All rights reserved</abstract>
  <subject>
    <topic>AQUIFERS - FLORIDA</topic>
  </subject>
  <subject>
    <topic>DATA PROCESSING - DATA ACQUISITION</topic>
  </subject>
  <subject>
    <topic>HYDROLOGY</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Groundwater, 24(3), p.351-356, 1986</title>
    </titleInfo>
  </relatedItem>
  <identifier type="uri">https://drive.google.com/file/d/1h9iwdaRAT9V2QEulUjMQuKRM1gOokfKz/view?usp=drivesdk</identifier>
  <location>
    <url>https://drive.google.com/file/d/1h9iwdaRAT9V2QEulUjMQuKRM1gOokfKz/view?usp=drivesdk</url>
  </location>
  <recordInfo>
    <recordContentSource authority="marcorg"/>
    <recordCreationDate encoding="marc">250602</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260521091529.0</recordChangeDate>
  </recordInfo>
</mods>
