<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01595nam a2200241Ia 4500</leader>
  <controlfield tag="003">MX-MdCICY</controlfield>
  <controlfield tag="005">20260521091229.0</controlfield>
  <datafield tag="040" ind1=" " ind2=" ">
    <subfield code="c">CICY</subfield>
  </datafield>
  <datafield tag="090" ind1=" " ind2=" ">
    <subfield code="a">B-10958</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
    <subfield code="a">Effect of anode flow field design on the performance of liquid feed direct methanol fuel cells</subfield>
  </datafield>
  <datafield tag="490" ind1="0" ind2=" ">
    <subfield code="v">Electrochimica Acta, 50, p.3243-3252, 2005</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
    <subfield code="a">In this work, we investigated experimentally the effect of the anode flow field design on the performance of a DMFC. Single serpentine (SSFF)and parallel flow fields (PFF)with different sizes were designed, fabricated and tested. The experimental results showed that the DMFCs equipped with the SSFFs yielded better performance than those with the PFFs. It was also found that gas bubbles blocked the flow channels in the PFF at low methanol solution flow rates and high current densities, but this channel-blocking phenomenon was never found in the SSFF under all the test conditions in the present work. Studies on the effects of SSFF design parameters revealed that both open ratio and flow channel length had significant influences on the cell performance and pressure drop. An open ratio of around 50</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="4">
    <subfield code="a">DIRECT METHANOL FUEL CELLS</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="4">
    <subfield code="a">FLOW FIELDS</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="4">
    <subfield code="a">OPEN RATIO</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="4">
    <subfield code="a">RIB SIZE</subfield>
  </datafield>
  <datafield tag="650" ind1="1" ind2="4">
    <subfield code="a">PRESSURE DROP</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2="2">
    <subfield code="a">Yang, H.</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2="2">
    <subfield code="a">Zhao, T.S.</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
    <subfield code="u">https://drive.google.com/file/d/1NwBqbze8c1pyULDzI53Iw6hrvu3sBK5Y/view?usp=drivesdk</subfield>
    <subfield code="z">Para ver el documento ingresa a Google con tu cuenta: @cicy.edu.mx</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="2">Loc</subfield>
    <subfield code="c">REF1</subfield>
  </datafield>
  <controlfield tag="008">250602s9999    xx |||||s2   |||| ||und|d</controlfield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">21128</subfield>
    <subfield code="d">21128</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="2">Loc</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="8">F1</subfield>
    <subfield code="a">CICY</subfield>
    <subfield code="b">CICY</subfield>
    <subfield code="c">RE</subfield>
    <subfield code="d">2025-06-25</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">B-10958</subfield>
    <subfield code="r">2025-06-25 14:06:41</subfield>
    <subfield code="w">2025-06-25</subfield>
    <subfield code="y">REF1</subfield>
  </datafield>
</record>
