<?xml version="1.0" encoding="UTF-8"?>
<mods xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" version="3.1" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
  <titleInfo>
    <title>Behavior of concrete cylinders confined by carbon-composite tapes and prestressed yarns 1. Experimental data</title>
  </titleInfo>
  <name type="personal">
    <namePart>Tamuzs, V.</namePart>
  </name>
  <name type="personal">
    <namePart>Tepfers, R.</namePart>
  </name>
  <name type="personal">
    <namePart>You, S.C.</namePart>
  </name>
  <name type="personal">
    <namePart>Rousakis, T.</namePart>
  </name>
  <name type="personal">
    <namePart>Repelis, I.</namePart>
  </name>
  <name type="personal">
    <namePart>Skruls, V.</namePart>
  </name>
  <name type="personal">
    <namePart>Vilks, U.</namePart>
  </name>
  <typeOfResource>text</typeOfResource>
  <originInfo>
    <place>
      <placeTerm type="code" authority="marccountry">xx</placeTerm>
    </place>
    <dateIssued encoding="marc">9999</dateIssued>
    <issuance>monographic</issuance>
  </originInfo>
  <language>
    <languageTerm authority="iso639-2b" type="code">und</languageTerm>
  </language>
  <physicalDescription>
    <form authority="marcform">electronic</form>
  </physicalDescription>
  <abstract>The results of a comprehensive test program for the mechanical behavior of round concrete specimens confined by carbon-fiber epoxy tapes and prestressed carbon yarns are reported. Five different concrete batches of compressive strength from 20 to 100 MPa and the confinement of various thickness and pretension level were investigated. The specimens, which were subjected to monotonic or repeated compressive loadings, showed a nonlinear stress-strain behavior with a significant ductility and increased ultimate strength, in contrary to the brittle behavior of plain concrete. The limit of linearity on the stress-strain diagrams of the confined concrete roughly coincided with the ultimate strength of plain concrete. Above this limit, the damage accumulation and plastic deformations proceeded in the confined specimens. This fact was evidenced by the increasing slope of deformation diagrams in unloadings and repeated loadings and by the pronounced residual strains. The limit of linearity could be raised significantly by pretension of the carbon yarns during their winding.</abstract>
  <subject>
    <topic>CONCRETE</topic>
  </subject>
  <subject>
    <topic>CYLINDRICAL SPECIMENS</topic>
  </subject>
  <subject>
    <topic>COMPOSITE CONFINEMENT</topic>
  </subject>
  <subject>
    <topic>COMPRESSIVE LOADING</topic>
  </subject>
  <subject>
    <topic>PLASTICITY</topic>
  </subject>
  <subject>
    <topic>DAMAGE</topic>
  </subject>
  <subject>
    <topic>STRENGTH</topic>
  </subject>
  <relatedItem type="series">
    <titleInfo>
      <title>Mechanics of Composite Materials, 42(1), p.13, 2006</title>
    </titleInfo>
  </relatedItem>
  <identifier type="uri">https://drive.google.com/file/d/1MIOQS8qqm5I78LMlEMQi9EdTH25ww4Nd/view?usp=drivesdk</identifier>
  <location>
    <url>https://drive.google.com/file/d/1MIOQS8qqm5I78LMlEMQi9EdTH25ww4Nd/view?usp=drivesdk</url>
  </location>
  <recordInfo>
    <recordContentSource authority="marcorg"/>
    <recordCreationDate encoding="marc">250602</recordCreationDate>
    <recordChangeDate encoding="iso8601">20260521091048.0</recordChangeDate>
  </recordInfo>
</mods>