CICY GOBIERNO DE MÉXICO · SECIHTI

BIBLIOTECA

CICY.mxBiblioteca › Catálogo en línea

Induction heating of electrically conductive porous asphalt concrete

Material type: TextSeries: ; Construction and Building Materials, 24(7), p.1207-1213, 2010Contained works:
  • Liu, Q
  • Schlangen, E
  • García, A
  • Van De Ven, M
Subject(s): Online resources: Abstract: In this research, an electrically conductive porous asphalt concrete, used for induction heating, was prepared by adding electrically conductive filler (steel fibers and steel wool)to the mixture. The main purpose of this paper is to examine the electrical conductivity and the indirect tensile strength of this conductive porous asphalt concrete and prove that it can be heated via induction heating. It was found that, to make porous asphalt concrete electrically conductive, long steel wool with small diameter is better than short steel fibers with bigger diameter. However, steel fibers with short length and big diameter have better strength reinforcement capability than steel wool with long length and small diameter. It was also proved that conductive porous asphalt concrete containing steel wool can be easily heated via induction heating. Finally, 10
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
REF1 CICY F1 B-13008 (Browse shelf(Opens below)) Available

In this research, an electrically conductive porous asphalt concrete, used for induction heating, was prepared by adding electrically conductive filler (steel fibers and steel wool)to the mixture. The main purpose of this paper is to examine the electrical conductivity and the indirect tensile strength of this conductive porous asphalt concrete and prove that it can be heated via induction heating. It was found that, to make porous asphalt concrete electrically conductive, long steel wool with small diameter is better than short steel fibers with bigger diameter. However, steel fibers with short length and big diameter have better strength reinforcement capability than steel wool with long length and small diameter. It was also proved that conductive porous asphalt concrete containing steel wool can be easily heated via induction heating. Finally, 10

There are no comments on this title.

to post a comment.