CICY GOBIERNO DE MÉXICO · SECIHTI

BIBLIOTECA

CICY.mxBiblioteca › Catálogo en línea

The effect of the MEA preparation procedure on both ethanol crossover and DEFC performance

Material type: TextSeries: ; Journal of Power Sources, 140(1), p.103-110, 2005Contained works:
  • Song, S
  • Wang, G
  • Zhou, W
  • Zhao, X
  • Sun, G
  • Xin, Q
  • Kontou, S
  • Kontou, S
Subject(s): Online resources: Abstract: In the present work, the changes of Nafion®-115 membrane porosity in the presence of ethanol aqueous solutions of different concentrations were determined by weighing vacuum-dried and ethanol solution-equilibrated membranes. It was found that membrane porosity increases as ethanol concentration increases. Membrane electrode assemblies (MEAs)have been prepared by following both the conventional and the decal transfer method. The ethanol crossover through these two MEAs was electrochemically quantified by a voltammetric method. A 10 h stability test of direct ethanol fuel cell (DEFC)at a current density of 50mAcm-2 was carried out. It was found that the electrode preparation procedure has an obvious effect on ethanol crossover and direct ethanol fuel cell's performance and stability. The single DEFC test results showed that about 15 and 34
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
REF1 CICY F1 B-8118 (Browse shelf(Opens below)) Available

In the present work, the changes of Nafion®-115 membrane porosity in the presence of ethanol aqueous solutions of different concentrations were determined by weighing vacuum-dried and ethanol solution-equilibrated membranes. It was found that membrane porosity increases as ethanol concentration increases. Membrane electrode assemblies (MEAs)have been prepared by following both the conventional and the decal transfer method. The ethanol crossover through these two MEAs was electrochemically quantified by a voltammetric method. A 10 h stability test of direct ethanol fuel cell (DEFC)at a current density of 50mAcm-2 was carried out. It was found that the electrode preparation procedure has an obvious effect on ethanol crossover and direct ethanol fuel cell's performance and stability. The single DEFC test results showed that about 15 and 34

There are no comments on this title.

to post a comment.